Mining in an apartment or rental: power, heat, and lease reality
General information only, not financial advice and not legal advice. Lease terms and tenancy rules vary by building, lease and jurisdiction; the lease document and, where needed, the relevant tenancy authority are the deciding sources, not this guide. Nothing here predicts mining earnings.
A miner in a rental is often pictured as a small computer that happens to earn. The building experiences it differently: as a space heater that never switches off, attached to a fan that never quietens, drawing power every hour of every day. That picture, not the earnings picture, is the one a landlord, a lease and a circuit all respond to. The verdict up top, before the maths: a full-size ASIC is a poor fit for almost any apartment; a low-watt device can fit easily; and the space-heater class in between fits only with the circuit, the season and the lease all checked first, in that order.
Power: one miner against one circuit, in amps
Divide watts by volts to get amps. Worked at 120 V, the three device classes in this guide draw very different loads:
| Device class | Power draw | Amps at 120 V (calculated) | Heat into the room |
|---|---|---|---|
| Bitaxe-class solo miner | 15–25 W | 0.1–0.2 A | Negligible, light-bulb scale |
| Bitcoin space-heater miner | 800–3,000 W | 6.7–25 A | Replaces a standard electric space heater |
| Full-size ASIC (Antminer S21 class) | 3,500 W | 29 A at 120 V; ~14.6 A at 240 V | 3,000–3,500 W of heat per unit into living space |
Now set those figures against a circuit. A 15 A breaker at 120 V can supply at most 1,800 W in total, breaker rating multiplied by voltage, before any safety margin for a load that runs continuously rather than cycling like a kettle. The top of the space-heater range, 3,000 W, exceeds that entire circuit on its own. A full-size ASIC exceeds it nearly twice over at 120 V. The Bitaxe-class device, at a fifth of an amp, does not register in this conversation at all. No opinion is involved in any of that; it is multiplication, and it settles most apartment plans before noise or leases enter the discussion.
The running cost is the same arithmetic stretched over time. A device drawing 1,000 W continuously uses 24 kWh a day, roughly 720 kWh over a 30-day month. At the residential electricity rates in the home-versus-hosted comparison checked for this guide, $0.08 to $0.20 or more per kWh, against industrial rates of $0.04–$0.07, that single kilowatt costs about $58 to $144 a month, every month, whether the mining side performs or not. Scale it linearly: an 800 W heater-miner runs roughly $46–$115 a month in power alone at those rates. In a building where utilities are included in rent, that cost lands on the landlord, which is precisely why the lease section below exists.
Heat: watts become BTU, and the season flips the sign
Every watt a miner draws ends up as heat in the room; converting at 3.412 BTU per hour per watt, a 1,000 W device delivers about 3,400 BTU/h, and a 3,000 W device about 10,200 BTU/h. Whether that heat is a feature or a problem depends entirely on the month.
In winter, the sourced framing is direct: space-heater miners in the 800–3,000 W range replace a standard electric space heater. A tenant who would run electric heat anyway is redirecting the same watts through a miner first. In summer the sign flips. The same 10,200 BTU/h must now be removed by air conditioning the tenant also pays to run, so the miner’s heat is bought twice, once to make it, once to shift it. In a small apartment with one cooling unit, a continuous multi-kilowatt heat source can exceed what the room’s cooling can offset, at which point the choice is a hot apartment or a switched-off miner. Spring and autumn sit between: heat that is welcome at night and unwelcome by afternoon. A year-round plan that only works in January is a three-month plan with nine months of improvisation attached.
Noise: the number neighbours hear through a wall
Industrial ASICs produce sound above 75 dB, with the hosting comparison listing 75–80 dB per unit for home mining. That is not a hum to sleep beside; it is a continuous mechanical noise, present at 3 a.m. exactly as at 3 p.m. in a building where other people’s bedrooms share the wall. Bitaxe-class devices sit at the opposite end: documented as silent, at 15–25 W. The space-heater class falls between by design, built to live in a room, but “between” still deserves a night’s honest thought, because tenancy complaints rarely cite decibels; they cite sleep.
The lease: clauses to search before any hardware arrives
Most residential leases include clauses limiting commercial activities that create excessive noise, heat or utility consumption, the three outputs a miner produces continuously. In master-metered buildings, where one meter serves the building, one tenant’s excess consumption raises costs for all residents, which converts a private hobby into a shared bill and, predictably, a dispute.
Landlords notice consumption spikes immediately, especially where they cover utilities. The Quebec landlords association reports tenants installing dozens of servers in apartments, with significant heat and high consumption, and advises owners to act against commercial use in residential housing. Landlords whose rent includes electricity are identified as most at risk, and therefore most attentive.
Search the lease text for these specific clauses:
- Commercial use or business activity, any clause restricting running a business, or commercial activity generally, from the unit.
- Utilities included / master-metered, who pays for electricity, and whether a fair-use or excess-use provision attaches to included utilities.
- Appliance and electrical limits, clauses restricting high-draw appliances, space heaters, or alterations to electrical service.
- Noise and nuisance, quiet-enjoyment and nuisance clauses a continuous 75 dB device could fall under.
- Alterations, anything requiring consent for new circuits or fixed installations, relevant the moment a 240 V line is contemplated.
If mining proceeds, written permission should name the device class and its wattage, state who bears the electricity cost and how it is measured, note the noise and heat arrangements, and set an end condition if complaints arise. A verbal yes to “a computer project” covers none of that. This is general information about what leases commonly contain, not advice on any specific lease, the document itself governs.
The tenant pre-flight
- Take the device’s maximum wattage and divide by the circuit voltage. Compare the amps against the breaker rating printed in the panel, remembering the device runs continuously.
- Run the monthly cost: watts ÷ 1,000 × 24 hours × 30 days × the per-kWh rate actually paid, or, if utilities are included, recognise whose bill the figure lands on.
- Convert watts to BTU/h and ask the summer question explicitly: can the unit’s cooling remove this heat, and at what extra cost?
- Check the noise figure against the building’s reality: shared walls, night hours, a roommate if any.
- Search the five lease clauses above, in the signed lease, not a summary.
- If every step passes, get permission in writing covering device, wattage, cost and complaints, before the hardware is ordered.
What success looks like: a device whose amps fit the circuit with room to spare, a monthly power figure the tenant can state without flinching, a summer plan for the heat, and a signed permission that names the actual machine, a setup no single complaint, bill or breaker trip can reframe as a surprise.
The scale decision
Three honest outcomes exist. The Bitaxe class, 15–25 W, silent, a fifth of an amp, fits any rental’s power, heat and noise reality, and its lease footprint is that of a small gadget; choose it when the goal is learning and participation at apartment scale. The space-heater class fits conditionally: winter heat genuinely replaced, a circuit that carries the chosen wattage, and written permission in hand; choose it only when all three hold at once. The full-size ASIC, 3,500 W, above 75 dB, 3,000–3,500 W of heat into living space, fails the apartment tests on arithmetic alone, and its realistic home is hosted or colocated space, where the industrial rates of $0.04–$0.07 per kWh also apply. Matching the machine to the building, rather than to the ambition, is the whole decision.
, Dex Carter, Tech Writer